Estimate spring rate (spring constant), load, stress and solid height for compression, extension and torsion springs, and load, rate and stress for Belleville washers (disc springs) and disc stacks. Switch between mm/N and in/lbf. Results are design estimates; send your drawing for a manufacturing review.
Spring rate is the force needed to deflect a spring by one unit of length. For a helical compression or extension spring it follows from Hooke's law, F = k·x, and the spring's geometry.
Carbon spring steel wire, d = 2 mm, OD = 20 mm (D = 18 mm), 10 total coils with closed and ground ends (Nₐ = 8), G = 79.3 GPa:
k = 79 300 × 2⁴ / (8 × 18³ × 8) ≈ 3.40 N/mm (19.4 lbf/in)
Spring steel disc, De = 40 mm, Di = 20.4 mm, t = 2.25 mm, l₀ = 3.15 mm (h₀ = 0.9 mm), E = 206 GPa, μ = 0.3, deflected to s = 0.75·h₀:
K₁ ≈ 0.686 · F(s = 0.675 mm) ≈ 6 500 N (1 461 lbf) · F(flat) ≈ 8 456 N
Spring rate, also called the spring constant, is the force required to compress or extend a spring by one unit of length, for example 3.4 N/mm. For a linear spring the force rises in proportion to deflection (F = k·x).
k = G·d⁴ / (8·D³·Nₐ), where G is the shear modulus, d the wire diameter, D the mean coil diameter and Nₐ the number of active coils. Doubling the wire diameter makes the spring 16 times stiffer; doubling the mean diameter makes it 8 times softer.
Yes. Both mean force per unit deflection. "Spring rate" is more common on spring drawings and catalogs; "spring constant" is the physics term from Hooke's law.
Multiply N/mm by 5.710 to get lbf/in, or divide lbf/in by 5.710 to get N/mm. For N/m, multiply N/mm by 1000.
Real springs vary with wire diameter tolerance, the actual number of active coils, end-coil contact, material modulus and pitch. The rate is also less linear near free length and solid height, so rate is commonly measured between about 20% and 80% of the available travel.
Yes. Send the calculated dimensions, the load you need at a working length, material, end type and quantity. Wanjin reviews feasibility, tolerances and test requirements against your drawing before sampling.
Use the Almen–László formula from DIN 2092 / EN 16984: F = [4E / (1 − μ²)] · [t⁴ / (K₁·De²)] · (s/t) · [(h₀/t − s/t)·(h₀/t − s/2t) + 1], where K₁ depends only on the diameter ratio De/Di. A DIN 2093 A 40 disc (40 × 20.4 × 2.25 mm) gives about 6.5 kN at 75% of its cone height.
Discs stacked in parallel (same direction) multiply the load at the same deflection; discs stacked in series (alternating direction) multiply the deflection at the same load. A stack of i series groups with n discs each carries about n times the single-disc load over i times its travel, with friction hysteresis from the parallel discs.
Estimates use nominal dimensions and typical room-temperature moduli. They are not a quotation, tolerance or acceptance value; feasibility, stress limits and fatigue life are confirmed in drawing review.