Spring Constant Units, Formula and How to Find It
Author: Jenny Xu
Published: Nov 10, 2026
Updated: Nov 10, 2026
The spring constant k is the force needed to change a spring's length by one unit: k = F / x. It is also called spring rate or stiffness. The SI unit is newtons per metre (N/m); spring makers usually quote N/mm, and US drawings use lbf/in.
Spring constant units and conversions
| Value | N/mm | N/m | lbf/in | kgf/mm |
|---|---|---|---|---|
| 1 N/mm | 1 | 1,000 | 5.710 | 0.1020 |
| 1 N/m | 0.001 | 1 | 0.00571 | 0.000102 |
| 1 lbf/in | 0.1751 | 175.1 | 1 | 0.01786 |
| 1 kgf/mm | 9.807 | 9,807 | 56.00 | 1 |
Torsion springs are rated in torque per angle, such as N·mm/deg or lbf·in/deg.
US spring catalogues often write lb/in when they mean lbf/in. A pound (lb) is a mass and a pound-force (lbf) is a force: 1 lbf = 4.448 N, the weight of a 1 lb mass under standard gravity. A spring rate is always a force per length, so read it as lbf/in.
Spring constant formulas
- Compression spring: F = k·x, where x is the deflection from free length.
- Extension spring: F = Fᵢ + k·x, where Fᵢ is the initial tension wound into the coils.
- Torsion spring: M = k′·θ, where M is torque and θ is the angle turned.
- Energy stored in a linear spring: U = ½·k·x², explained in Hooke's law and potential energy.
How to find the spring constant of a real spring
Measure two points rather than one. Compress the spring to two known lengths inside its working range and record the force at each. Then k = (F₂ − F₁) / (L₁ − L₂). Using points between about 20% and 80% of the available deflection avoids the uneven seating at the start of travel and the coil contact near solid height. The spring measuring guide covers the rest of the dimensions.
How to calculate k from the dimensions
For a round-wire helical compression or extension spring, k = G·d⁴ / (8·D³·Nₐ). G is the shear modulus of the material, d the wire diameter, D the mean coil diameter (outside diameter minus d), and Nₐ the number of active coils.
Example: music wire with G = 81,700 N/mm², d = 2 mm, outside diameter 20 mm so D = 18 mm, and 6 active coils. Then k = 81,700 × 2⁴ / (8 × 18³ × 6) = 4.67 N/mm, or 26.7 lbf/in. Compressing it 10 mm takes 46.7 N and stores about 0.23 J.
The formula shows why tolerances matter. If wire diameter rises 10%, the rate rises 46%. If the mean diameter rises 10%, the rate falls 25%. If the active coils rise 10%, the rate falls 9%. The spring rate calculator runs these formulas in mm or inches.
Springs in series and parallel
- Parallel (side by side, sharing the load): k = k₁ + k₂.
- Series (end to end, each carrying the full load): 1/k = 1/k₁ + 1/k₂.
Two equal springs give 2k in parallel and k/2 in series. The series and parallel guide works through unequal springs, dual-rate sets and disc spring stacks.
When the spring constant is not constant
Hooke's law holds only over the linear part of a spring's travel. The rate rises as coils touch near solid height. Conical springs with constant pitch get stiffer as their largest coils bottom out, and disc springs follow a curve set by the ratio of cone height to thickness. For those, specify force at two or more lengths instead of a single rate.
Key Takeaways
- k = F / x; 1 N/mm = 5.710 lbf/in.
- For a helical spring, k = G·d⁴ / (8·D³·Nₐ), so a 10% change in wire diameter moves the rate 46%.
- Find k from two force points inside the working range, not from one.